Research on the Parameters of Swirling Jets from Supply Units and the Efficiency of Indoor Air Purification from Urban Dust

Number of journal: 3-2026
Autors:

Litvinova N.A.,
Azarov V.N.

DOI: https://doi.org/10.31659/0044-4472-2026-3-54-61
УДК: 697.941

 

AbstractAbout AuthorsReferences
The results of studies of the parameters of swirling jets from supply units with air purification from dust of vertical surfaces of residential buildings are presented and their cleaning efficiency is estimated with determination of aerodynamic parameters using the proposed experimental installation. It is established that the efficiency of air purification of the supply unit from dust with a dispersion of 2.5–5 microns was 98.98%, with a dispersion of 8–10 microns – 99.34%. The paper presents empirical dependences of dust concentrations with particle sizes of 2.5–5 μm and 8–10 μm on the air velocity in the supply unit. According to the calculated data of the parameters of the supply jet in the service area, the air velocity corresponds to the permissible value for residential buildings, depending on the air flow rate. When comparing theoretical calculations and experimental data on air velocity on the axis of the inlet swirling jet at air flow rates of 90 and 140 m3/h, the difference was no more than 5.3–7.7%. With an increase in air flow rate from 90 to 300 m3/h, the coefficient of aerodynamic drag decreases by 1.3 times, and the pressure difference increases from 0.005 to 0.018 kPa. The results of the pressure difference and air aerodynamic resistance parameters are necessary for the justification and selection of a swirling supply fan.
N.A. LITVINOVA1, Doctor of Sciences (Engineering) (This email address is being protected from spambots. You need JavaScript enabled to view it.);
V.N. AZAROV2, Doctor of Sciences (Engineering) (This email address is being protected from spambots. You need JavaScript enabled to view it.)

1 Tyumen Industrial University (38, Volodarsky Street, Tyumen, 625005, Russian Federation)
2 Volgograd State Technical University (1, Akademicheskaya Street, Volgograd, 400005, Russian Federation)

1. Азаров В.Н., Николенко М.А., Боровков Д.П., Калюжина Е.А. Снижение пылевых выбросов при производстве асфальтобетона // Известия высших учебных заведений. Строительство. 2024. № 2 (782). С. 63–79. EDN: ­PRUJFV. https://doi.org/10.32683/0536-1052-2024-782-2-63-79
1. Azarov V.N., Nikolenko M.A., Borovkov D.P., Kalyuzhina E.A. Reduction of dust emissions during the production of asphalt concrete. Izvestiya of Higher Educational Institutions. Construction. 2024. No. 2 (782), рp. 63–79. (In Russian). EDN: ­PRUJFV. https://doi.org/10.32683/0536-1052-2024-782-2-63-79
2. Азаров В.Н., Бурлаченко А.О. Организация строительного производства с учетом экологичной безопасности принимаемых решений // Биосферная совместимость: человек, регион, технологии. 2023. № 1 (41). С. 76–83. EDN: ­KKXFQT. https://doi.org/10.21869/2311-1518-2023-41-1-76-83
2. Azarov V.N., Burlachenko A.O. Organization of construction production taking into account the ecological safety of the decisions made. Biosfernaya Sovmestimost’: Chelovek, Region, Tekhnologii. 2023. No. 1 (41), pp. 76–83. (In Russian). EDN: ­KKXFQT. https://doi.org/10.21869/2311-1518-2023-41-1-76-83
3. Зиганшин А.М., Еремина С.В. Компьютерное моделирование течения в симметричном вентиляционном тройнике круглого сечения на слияние // Строительные конструкции, здания и сооружения. 2023. № 1 (2). С. 25–31. EDN: ­HKLXYV
3. Ziganshin A.M., Eremina S.V. Computer modeling of flow in a symmetrical round-section ventilation tee for fusion. Stroitel’nye Konstrukcii, Zdaniya i Sooruzheniya. 2023. No. 1 (2), pp. 25–31. (In Russian). EDN: ­HKLXYV
4. Logachev K.I., Popov E.N., Kozlov T.A., et al. Numerical and experimental studies of airflows at exhaust hoods with inlet extensions. Building and Environment. 2024. Vol. 261, pp. 111753. EDN: ­QRTGOM. https://doi.org/10.1016/j.buildenv.2024.111753
5. Logachev K.I., Popov E.N., Kozlov T.A., et al. Improved aerodynamic performance of the exhaust hood with triple-faced flange. Journal of Building Engineering. 2024. Vol. 91, pp. 109664. EDN: ­QWXXAE. https://doi.org/10.1016/j.jobe.2024.109664
6. Bennia A., Reffas A., Khan M.A.H., Mohamadi H.E., Lateb M., Fellouah H. Experimental and numerical dynamic investigation of a swirling jet: application to improve the efficiency of air diffusion in an occupied zone. Journal of Applied Fluid Mechanics. 2023. No. 16 (9), pp. 1729–1741. EDN: ­WJVYHG. http://doi.org/10.47176/jafm.16.09.1805
7. Liu M., Gao R., Zhao Y., Li A. Swirl diffuser shape optimization based on a comprehensive evaluation index for both winter and summer conditions. Indoor and Built Environment. 2025. No. 34 (4), pp. 736–750. http://doi.org/10.1177/1420326X251319479
8. Ma W., Xu C., Yi S., Wang L., Zhang C., Nielsen P.V. Turbulent momentum transfer of isothermal multiple swirling jets and preliminary exploration of its application in displacement ventilation. Building and Environment. 2025. No. 269, pp. 112460. https://doi.org/10.1016/j.buildenv.2024.112460
9. Zahout N., Braikia M., Khelil A., Naji H. Thermal and dynamic characterization of a multi-jet system with different geometry diffusers. Journal of Thermal Engineering. 2024. No. 10 (2), pp. 404–429. EDN: ­NLNQRH. http://dx.doi.org/10.18186/thermal.1456643
10. Гольцов А.Б., Логачев К.И., Аверкова О.А. и др. Численное моделирование воздушного потока в аспирационной воронке с выравнивающим устройством // Известия высших учебных заведений. Строительство. 2024. № 7 (787). С. 64–75. EDN: ­ECUIGS. https://doi.org/10.32683/0536-1052-2024-787-7-64-75
10. Goltsov A.B., Logachev K.I., Averkova O.A., et al. Numerical modeling of air flow in an aspiration funnel with an equalizing device. Izvestiya of Higher Educational Institutions. Construction. 2024. No. 7 (787), pp. 64–75. (In Russian). EDN: ­ECUIGS. https://doi.org/10.32683/0536-1052-2024-787-7-64-75
11. Литвинова Н.А., Азаров В.Н. Эффективность работы стеновых клапанов приточной принудительной вентиляции с очисткой воздуха в многоквартирных жилых зданиях // Жилищное строительство. 2023. № 10. С. 70–76. EDN: ­SHURFJ. https://doi.org/10.31659/0044-4472-2023-10-70-76
11. Litvinova N.A., Azarov V.N. Efficiency of wall valves for forced supply ventilation with air purification in apartment buildings. Zhilishchnoe Stroitel’stvo [Housing Construction]. 2023. No. 10, pp. 70–76. (In Russian). EDN: ­SHURFJ.
https://doi.org/10.31659/0044-4472-2023-10-70-76
12. Сергина Н.М., Симаков В.С., Бакин Н.С. и др. Применение метода отсечения для исследования распределения массы частиц пыли по диаметрам // Вестник Волгоградского государственного архитектурно-строительного университета. Сер.: Строительство и архитектура. 2025. № 4 (101). С. 216–227. EDN: ­OTWENW. https://doi.org/10.35211/18154360-2025-4-216
12. Sergina N.M., Simakov V.S., Bakin N.S., et al. Application of the cut-off method for studying the distribution of dust particle mass by diameter. Vestnik of the Volgograd State University of Architecture and Civil Engineering. Series: Construction and Architecture. 2025. No. 4 (101), pp. 216–227. (In Russian). EDN: ­OTWENW. https://doi.org/10.35211/18154360-2025-4-216

For citation: Litvinova N.A., Azarov V.N. Research on the parameters of swirling jets from supply units and the efficiency of indoor air purification from urban dust. Zhilishchnoe Stroitel'stvo [Housing Construction]. 2026. No. 3, pp. 54–61. (In Russian). https://doi.org/10.31659/0044-4472-2026-3-54-61