About Errors Engineering and Deviceing Anchor Piles, Performed by Discharge-Pulse Technology

Number of journal: 12-2020
Autors:

Samarin D.G.,
Filippovich A.A.,
Ustyuzhanin V.L.

DOI: https://doi.org/10.31659/0044-4472-2020-12-13-21
УДК: 621.6.072

 

AbstractAbout AuthorsReferences
The article examines a case from the practice of geotechnical construction, when errors in the calculations of anchor piles performed by discharge-pulse technology (DPT anchor) and deviations from engineering solutions could lead to an emergency. During excavation of the foundation pit, an underground parking lot under construction, the enclosing structure, fixed with DPT anchors, received unacceptable displacements. Calculations established that the bearing capacity of the DPT anchors on the ground was overestimated up to 3 times. In addition, the analysis of the available materials on this object allowed the authors to identify serious violations in the construction of the latter. It is shows that when carrying out work on the preliminary tension of the DPT anchors, in some cases, already with an effort of 10 tons, there is a loss of their bearing capacity along the ground. As a result, it became necessary to redesign the anchorage.
D.G. SAMARIN, Candidate of Sciences (Engineering) (This email address is being protected from spambots. You need JavaScript enabled to view it.),
A.A. FILIPPOVICH, Candidate of Sciences (Engineering),
V.L. USTYUZHANIN, Engineer

Tomsk State University of Architecture and Building (2, Solyanaya Sq.,Tomsk, 634003, Russian Federation)

1. Dzhantimirov Kh.A., Kryuchkov S.A., Smirnov P.V. Geotechnical technologies based on electrochemical explosion. Proceedings of the International Scientific and Practical Conference on Soil Mechanics, foundation Engineering and Transport Construction. Perm. 2004. Vol. 1, pp. 46–58. (In Russian).
2. Dzhantimirov Kh.A., Kryuchkov S.A., Smirnov P.V. Geotechnical technologies based on electrochemical explosion. Proceedings of the International Conference on Geotechnics: Reconstruction of Historic Cities and Geotechnical Construction. St. Petersburg. 2003. Vol. 2, pp. 24–30. (In Russian).
3. Kubetsky V.L. The use of piles-RIT in the foundations of high-rise buildings. Vestnik MGSU. 2012. No. 4. pp. 240–245. (In Russian).
4. Sokolov N.S., Sokolov A.N., Sokolov S.N., Glushkov V.E., Glushkov A.E. Calculation of Increased Bearing Capacity Bored Piles. Zhilishchnoe Stroitel’stvo [Housing Construction]. 2017. No. 11, pp. 20–26. (In Russian).
5. Eremin V.Ya., Eremin A.V. High-rise buildings – a reliable foundation. Proceedings of the International Scientific and Technical Conference. Problems of soil mechanics and foundation engineering in difficult soil conditions. Ufa, October 3–5. 2006. Vol. 1, pp. 69–75. (In Russian).
6. Samarin D.G. Device of a trunk of the stuffed piles with use of the electric discharges. Izvestiya vysshikh uchebnykh zavedenii. Stroitel’stvo. 2005. No. 3, pp. 120–123. (In Russian).
7. Sokolov N.S., Viktorova S.S., Fedorova T.G. Piles of increased bearing capacity. Materials of the 8th All-Russian (2nd International) conference. New in architecture, design of building structures and reconstruction (NASKR-2014). Cheboksary. 2014, pp. 411–415. (In Russian).
8. Sokolov N.S., Ryabinov V.M. On one method for calculating the bearing capacity of ERT bore-injection piles. Osnovaniya, fundamenty i mekhanika gruntov. 2015. No. 1, pp. 10–13. (In Russian).
9. Sokolov N.S., Ryabinov V.M. On the efficiency of drilling injection piles with multiple widening using electric discharge technology. Geotekhnika. 2016. No. 2, pp. 28–32. (In Russian).
10. Sokolov N.S., Ryabinov V.M. Features of the device and calculation of bored injection piles with multiple widening. Geotekhnika. 2016. No. 3, pp. 60–65. (In Russian).
11. Ryabinov V.M., Gorbushin A.V. Possibilities of the electrical discharge technology application at the construction on the weak soils. Osnovaniya, fundamenty i mekhanika gruntov. 2008. No. 6, pp. 10–13. (In Russian).
12. Sokolov N.S. About an erroneous method of the booster injection piles arrangement using the electrical discharge technology. Zhilishchnoe Stroitel’stvo [Housing Construction]. 2016. No. 11, pp. 20–28 (In Russian).
13. Polishchuk A.I., Samarin D.G., Filippovich A.A. Results of modeling processes of interaction of foundations with clay soil. Vestnik TGASU. 2013. No. 1 (38), pp. 253–259. (In Russian).
14. Polishchuk A.I., Samarin D.G., Osipov S.P., Filippovich A.A. The research of joint behavior of sallow foundation with strengthening injection piles in clay soil. Vestnik TGASU. 2014. No. 3 (44), pp. 177–190. (In Russian).

For citation: Samarin D.G., Filippovich A.A., Ustyuzhanin V.L. About errors engineering and deviceing anchor piles, performed by discharge-pulse technology. Zhilishchnoe Stroitel’stvo [Housing Construction]. 2020. No. 12, pp. 13–21. (In Russian). DOI: https://doi.org/10.31659/0044-4472-2020-12-13-21